Comfortline Inverter 9kW

Item No. 3096030013
Comfortline Inverter is powered by inverter compressor, it can adjust heating capacity from 20% to 100% intelligently according to different heating demands. When season starts and heating demand is high, the Comfortline Inverter runs at 100% compressor & fan speed for fast heating. When
Read full description
This product cannot be ordered at the moment.
Description

Comfortline Inverter is powered by inverter compressor, it can adjust heating capacity from 20% to 100% intelligently according to different heating demands.

When season starts and heating demand is high, the Comfortline Inverter runs at 100% compressor & fan speed for fast heating.

When maintaining the pool temperature, the Comfortline Inverter runs at low speed for energy saving with higher COP (efficiency rating).

General
Advantages

Spiral titanium heat exchanger: Enlarged 30% heat exchanging surface

HP-Booster technology: Enable COP 20% higher than On/Off HP in the market

Saginomiya: 4-way valve defrosting

Good to know

Average COP 9.9

Comfortline Inverter AVERAGE COP is 9.9 (Air 26°C/ Water 26°C/ Humidity 80%), which means lkW electricity consumption can provide up to 9.9kW heat in return. While On/Off HP can only provide 5kW heat as its COP is just around 5.

Specifications
Warranty 2 years warranty
5 years warranty on heat exchanger and compressor
Unit Weight 46 kg
Width 864 mm
Height 648 mm
Depth 359 mm
Connection IN 50 mm
Connection OUT 50 mm
Max input current 9.5 A
Advised Pool Volume 20 ~ 35
Operating Air temperature 0 ~43 °c
Performance Conditions Air 26°c - Water 26°c - Humidity 80%
Heating Capacity 9.0 kw
COP 10.6 ~ 6.8
COP at 50% capacity 9.6
Performance Conditions Air 15°c - Water 26°c - Humidity 70%
Heating Capacity 6.3 kw
COP 6.1 ~ 4.5
COP at 50% capacity 5.7
Sound pressure at 1m 40.6 ~ 52.5 dB(A)
Sound pressure at 10m 20.6 ~ 32.5 dB(A)
Sound pressure of 50% capacity at 1m 45.8 dB(A)
Exchanger Housing Shape Spiral
Exchanger Material Titanium tube in pvc
Casing Material Metal casing with plastic coating
Power Supply 230V/1 Ph/50Hz
Rated input power at air 15°C 0.36 ~ 1.40 kw
Rated input current at air 15°C 1.57 ~ 6..09 A
Advised water flux 3 ~ 4 m³/h
Max input current 9.5 A
Circuit Breaker 16 A
Power cord 3x1.5 mm²
General Technical Data
  • The advised pool volume indicated applies under following conditions: Swimming pool is well covered; system runs at least 15 hours per day;
  • The final specs will be in accordance with the specs on the product.
    Loading
    Loading
    if (Sana.IsProfilerEnabled) { }
    Icons made by Freepik from www.flaticon.com is licensed by CC 3.0 BY