Performance talks
Full-inverter HP brings you half running cost and 10 times quieter swimming environment based on AVERAGE performance. When season starts, the Full-inverter HP runs at 100% capacity to heat up the pool in the first few days. After that, the Full-inverter HP runs at AVERAGE 50% capacity to maintain the desired pool temperature.
Advantages |
Average 10 Times QuieterAll Inverter+ models are with twin-rotary compressor to minimise vibration. Running by AVERAGE 50% capacity to maintain pool temperature for whole swimming season, which means a 10 times quieter swimming environment. Soft Start FunctionWhen Inverter+ is turned on, the current will start from start from 0 Amps and slowly increase to the rated current in 2 minutes. It will not affect the house electricity system, while the frequent start current of an on/off HP is 5 times of rated current, it is a burden to the electricity system. Think BiggerWhen choosing an Inverter+ HP, we suggest to choose a correctly sized model so that the HP will run at lower speed most of the time. It will bring you more benefits:
|
Good to know |
Correct selectionWhen you select an Inverter+ which has been correctly sized, this ideal investment brings you:
|
Warranty |
3 years warranty 10 years on the compressor 10 years on heat exchanger |
Unit Weight | 50 kg |
Width | 954 mm |
Height | 648 mm |
Depth | 349 mm |
Connection IN | 50 mm |
Connection OUT | 50 mm |
Max input current | 11 A |
Advised Pool Volume | 30 ~ 55 m³ |
Advised Pool Volume in Silence Mode | 35 m³ |
Operating Air temperature | -7 ~43 °c |
Performance Conditions | Air 26°c - Water 26°c - Humidity 80% |
Heating Capacity | 13.0 kw |
COP | 15.4 ~ 7.3 |
COP at 50% capacity | 11.0 |
Performance Conditions | Air 15°c - Water 26°c - Humidity 70% |
Heating Capacity | 9.0 kw |
COP | 7.7 ~ 4.8 |
COP at 50% capacity | 6.8 |
Sound pressure at 1m | 42.1 ~ 50.7 dB(A) |
Sound pressure at 10m | 22.1 ~ 30.7 dB(A) |
Sound pressure of 50% capacity at 1m | 45.7 dB(A) |
Compressor Type | Twin-rotary Mitsubishi DC inverter |
Exchanger Housing Shape | Spiral |
Exchanger Material | Titanium tube in pvc |
Casing Material | Aluminum - alloy |
Power Supply | 230V/1 Ph/50Hz |
Rated input power at air 15°C | 0.23 ~ 1.81 kw |
Rated input current at air 15°C | 1.00 ~ 7.87 A |
Advised water flux | 4 ~ 6 m³/h |
Max input current | 11 A |
Circuit Breaker | 16 A |
Power cord | 3x2.5 mm² |
General Technical Data |
The specified pool volumes are only valid under the following conditions: Swimming pool should be covered during the night. Circulation pump runs at least 15 hours a day. Heating from 1 May to 15 September. If these conditions are not met, please choose a larger model. |